A vertical atmosphere furnace designed for calcination, reduction and activation of catalysts under controlled gas. Gas is passed through the sample bed for uniform gas-solid contact; it operates up to 1200 °C under vacuum and inert/reducing gas.
| Maximum temperature | 1200 °C (short-term) |
| Rated working temperature | 1100 °C |
| Working pressure | Vacuum – atmospheric pressure |
| Chamber size | Ø80 × 220 mm |
| Constant-temperature zone | 80 mm |
| Heated length | 220 mm |
| Tube size | Ø40 / Ø50 × 750 mm |
| Heating rate | 0–20 °C/min (recommended: 0–10 °C/min) |
| Power | 3 kW |
| Weight | 45 kg |
| Temperature control | PID, programmable segments, ±1 °C |