LAB MATERYAL
Select Language
Currency Selection
  • Neware CT-8002S Portable Battery Testing System ±5 V / 100 mA – with CV and EIS (2 Channels)

Neware CT-8002S Portable Battery Testing System ±5 V / 100 mA – with CV and EIS (2 Channels)

Product code : LM-BT-CT8002S-EIS         Comments (0)        Add Comment
Marka :  Neware
-
+

The CT-8002S-EIS combines precision charge-discharge testing with cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) in a single portable instrument. CV scans and impedance measurements can be run between cycles without moving the cell to a separate potentiostat, saving time in aging, interfacial resistance and electrode reaction studies.

Key Features

  • 2 independent channels, portable benchtop housing (~3 kg)
  • -5 V to +5 V operation (discharge down to negative voltage)
  • 6 current ranges (0.1 / 1 / 5 / 10 / 50 / 100 mA), minimum output current 0.2 µA
  • Voltage & current accuracy ±0.01% F.S., stability 0.02% F.S.
  • Current response time ≤20 µs, 1000 Hz recording (1 ms interval)
  • Cyclic voltammetry (CV) scans can be inserted into charge-discharge programs; scan rate 0.01 mV/s – 1 V/s
  • Electrochemical impedance spectroscopy (EIS): 10 mHz – 200 kHz
  • CC, CV, CP, CC-CV charge/discharge; DCIR, pulse simulation and GITT tests
  • 24-bit AD / 16-bit DA resolution; automatic switching between current ranges
  • Bipolar linear circuit: current crosses zero smoothly with no charge/discharge switching delay (manufacturer data)
  • Four-wire connection, dual closed-loop constant current / constant voltage control
  • Offline testing and power-failure protection (manufacturer data)
  • Compact and lightweight: can be used together with other instruments for in-situ measurements
  • Simultaneous CV and EIS on both channels; impedance measurement runs alongside charge-discharge testing

Technical Specifications

ModelCT-8002S-5V100mA-EIS
Channels2
Voltage range-5 V – +5 V
Current ranges0.1 mA / 1 mA / 5 mA / 10 mA / 50 mA / 100 mA
Minimum output current0.2 µA
CV cut-off current0.1 µA / 1 µA / 5 µA / 10 µA / 50 µA / 0.1 mA (by range)
Voltage & current accuracy±0.01% F.S.
StabilityVoltage 0.02% F.S., power 0.04% F.S.
Output power0.5 W / channel
Current response / conversion time≤20 µs
Recording frequency1000 Hz (minimum interval 1 ms)
Cycles / steps1–65535 cycles, ≤255 steps
CV scan rate0.01 mV/s – 1 V/s
EIS frequency range10 mHz – 200 kHz
ResolutionAD 24-bit / DA 16-bit
ConnectionFour-wire
Data exportExcel, TXT, CSV, PDF, graph
Cell connectionAlligator clip or polymer fixture
Power supplyAC 110 / 220 V ±10%, 50/60 Hz, 50 W
Dimensions / weight127 × 226 × 48 mm / ~3 kg

Applications

  • Cell diagnostics and aging studies with EIS
  • Interfacial (SEI) resistance analysis
  • Cyclic voltammetry and electrode reaction studies
  • In-situ measurements in battery materials research
  • Coin cell and small-cell R&D testing

The price shown is for one test unit in standard configuration; channel count, cabinet/rack configuration, software and accessories are confirmed at quotation stage.

★
★
★
★
★
Total 0 Comment made


Thank you for your comment. Your comment will be published after it is done.
Comment on you
Verification Code