Select Language
Currency Selection
  • Silver (Ag) GDE Cathode - CO₂RR (10 × 10 cm²)

Silver (Ag) GDE Cathode - CO₂RR (10 × 10 cm²)

Product code : LM-EC-GDE-AG         Comments (0)        Add Comment
Marka :  Lab Materials
Model
-
+

The Silver (Ag) gas diffusion electrode (GDE) is a 10 × 10 cm electrode used on the cathode side of a CO₂ electrolyzer. A GDE is a porous electrode that lets gaseous CO₂ reach the catalyst directly, avoiding the current limit caused by its low solubility in water (hundreds of mA cm⁻² are possible). Silver is a classic metal catalyst that reduces CO₂ mainly to carbon monoxide (CO); hydrogen can form as a side product. Manufacturer reference selectivity is ≥95%.

The model code selects the option: CB standard, CT better stability, U enhanced gas transport, H enhanced flooding resistance. No solid-electrolyte (X) version is offered for this electrode. Flooding means electrolyte fills the pores and blocks CO₂, raising hydrogen formation. Catalyst loading is about 1 mg cm⁻² (manufacturer data); reference performance was measured in an MEA electrolyzer.

Key Features

  • Target product: CO; reference selectivity ≥95% (manufacturer data)
  • Gas-diffusion structure: CO₂ reaches the catalyst from the gas phase, suited to high-current-density operation
  • 10 × 10 cm size; catalyst loading ~1 mg cm⁻² (manufacturer data)
  • Standard (CB) and better-stability (CT) options
  • Enhanced gas transport (U) and enhanced flooding resistance (H) options; combined versions (CBUH, CTUH)
  • High CO Faradaic efficiency on Ag cathodes in zero-gap cells is reported in the literature; anolyte concentration, temperature and pressure affect the result
  • Reference performance measured in an MEA electrolyzer; may vary with conditions

Technical Specifications

Product type CO₂RR cathode gas diffusion electrode (GDE)
Catalyst Silver (Ag)
Size 10 × 10 cm (100 cm²)
Target product CO
Reference selectivity (manufacturer data) ≥95%
Catalyst loading ~1 mg cm⁻² (manufacturer data)
Options (model code) CB standard; CT better stability; U enhanced gas transport; H enhanced flooding resistance (CBU, CTU, CBH, CTH, CBUH, CTUH)
Reference test cell Membrane electrode assembly (MEA) electrolyzer
Notes Selectivity varies with test conditions (electrolyte, temperature, pressure, current density); catalyst/electrode preparation and testing services are not included

Available Options

Model Description
Ag-CB (Standard) Standard
Ag-CT (Better stability) Better stability
Ag-CBU (Enhanced gas transport) Enhanced gas transport
Ag-CTU (Better stability, enhanced gas transport) Better stability, enhanced gas transport
Ag-CBH (Enhanced flooding resistance) Enhanced flooding resistance
Ag-CTH (Better stability, enhanced flooding resistance) Better stability, enhanced flooding resistance
Ag-CBUH (Enhanced gas transport, enhanced flooding resistance) Enhanced gas transport, enhanced flooding resistance
Ag-CTUH (Better stability, enhanced gas transport, enhanced flooding resistance) Better stability, enhanced gas transport, enhanced flooding resistance

For sizes and specifications not listed above, you can request a custom quotation through the Quote Form.

Applications

  • CO₂RR MEA (zero-gap) electrolyzer testing
  • GDE flow-cell studies
  • Comparing stability and flooding behavior across CB / CT / U / H options
  • Screening operating parameters such as anolyte/cation type, temperature, pressure and CO₂ flow
  • Optimizing cell and operating conditions for CO production
★
★
★
★
★
Total 0 Comment made


Thank you for your comment. Your comment will be published after it is done.
Comment on you
Verification Code


Thank you for your question. You will be notified by email once your question has been answered.
Click to Ask a Question
  No questions have been asked for this product yet.