  • Tin (Sn) GDE Cathode - CO₂RR (10 × 10 cm²)

Tin (Sn) GDE Cathode - CO₂RR (10 × 10 cm²)

Product code : LM-EC-GDE-SN         Comments (0)        Add Comment
Marka :  Lab Materials
Model
-
+

The Tin (Sn) gas diffusion electrode (GDE) is a 10 × 10 cm electrode used on the cathode side of a CO₂ electrolyzer. A GDE is a porous electrode that lets gaseous CO₂ reach the catalyst directly, avoiding the current limit caused by its low solubility in water (hundreds of mA cm⁻² are possible). Tin reduces CO₂ toward formate; surface SnO₂ is reduced to metallic Sn in operation, which is reported as the active site. In neutral/alkaline media the product is a formate salt; in solid-electrolyte cells it can be collected as formic acid. Manufacturer reference selectivity is ≥90% (X types ≥75%).

The model code selects the option: CB standard, CT better stability, U enhanced gas transport, H enhanced flooding resistance; X marks versions suitable for solid-electrolyte cells (CBX, CTX, CBUX, CTUX). Flooding means electrolyte fills the pores and blocks CO₂, raising hydrogen formation. Catalyst loading is about 1 mg cm⁻² (manufacturer data); reference performance was measured in an MEA electrolyzer.

Key Features

  • Target product: formate (the anion of formic acid); reference selectivity ≥90% (X types ≥75%; manufacturer data)
  • Gas-diffusion structure: CO₂ reaches the catalyst from the gas phase, suited to high-current-density operation
  • 10 × 10 cm size; catalyst loading ~1 mg cm⁻² (manufacturer data)
  • Standard (CB) and better-stability (CT) options
  • Enhanced gas transport (U) and enhanced flooding resistance (H) options; combined versions (CBUH, CTUH)
  • X versions are suitable for solid-electrolyte cells
  • Tin-based catalysts have been reported to produce formate at high current density in MEA electrolyzers; results depend on the catalyst and operating conditions
  • Reference performance measured in an MEA electrolyzer; may vary with conditions

Technical Specifications

Product type CO₂RR cathode gas diffusion electrode (GDE)
Catalyst Tin (Sn)
Size 10 × 10 cm (100 cm²)
Target product formate (the anion of formic acid)
Reference selectivity (manufacturer data) ≥90% (X types ≥75%)
Catalyst loading ~1 mg cm⁻² (manufacturer data)
Options (model code) CB standard; CT better stability; U enhanced gas transport; H enhanced flooding resistance (CBU, CTU, CBH, CTH, CBUH, CTUH); X solid-electrolyte compatible (CBX, CTX, CBUX, CTUX)
Reference test cell Membrane electrode assembly (MEA) electrolyzer
Notes Selectivity varies with test conditions (electrolyte, temperature, pressure, current density); catalyst/electrode preparation and testing services are not included

Available Options

Model Description
Sn-CB (Standard) Standard
Sn-CT (Better stability) Better stability
Sn-CBU (Enhanced gas transport) Enhanced gas transport
Sn-CTU (Better stability, enhanced gas transport) Better stability, enhanced gas transport
Sn-CBH (Enhanced flooding resistance) Enhanced flooding resistance
Sn-CTH (Better stability, enhanced flooding resistance) Better stability, enhanced flooding resistance
Sn-CBUH (Enhanced gas transport, enhanced flooding resistance) Enhanced gas transport, enhanced flooding resistance
Sn-CTUH (Better stability, enhanced gas transport, enhanced flooding resistance) Better stability, enhanced gas transport, enhanced flooding resistance
Sn-CBX (Suitable for solid-electrolyte cells) Suitable for solid-electrolyte cells
Sn-CTX (Suitable for solid-electrolyte cells, better stability) Suitable for solid-electrolyte cells, better stability
Sn-CBUX (Suitable for solid-electrolyte cells, enhanced gas transport) Suitable for solid-electrolyte cells, enhanced gas transport
Sn-CTUX (Suitable for solid-electrolyte cells, better stability, enhanced gas transport) Suitable for solid-electrolyte cells, better stability, enhanced gas transport

For sizes and specifications not listed above, you can request a custom quotation through the Quote Form.

Applications

  • CO₂RR MEA (zero-gap) electrolyzer testing
  • GDE flow-cell studies
  • Comparing stability and flooding behavior across CB / CT / U / H options
  • Screening operating parameters such as anolyte/cation type, temperature, pressure and CO₂ flow
  • Salt-free formate/formic acid solution production in solid-electrolyte cells (X versions)
★
★
★
★
★
Total 0 Comment made


Thank you for your comment. Your comment will be published after it is done.
Comment on you
Verification Code


Thank you for your question. You will be notified by email once your question has been answered.
Click to Ask a Question
  No questions have been asked for this product yet.
E-Newsletter
Do you want to be informed first about discounted products and opportunities?
softtr® | Profesyonel E-Ticaret Sistemleri ile hazırlanmıştır.